nGenuity™ Patient Monitor
User Configurable | Mini-Trends | Optional CO2
Improve patient outcomes with a comprehensive, user-configurable patient monitoring system covering the needs of multiple departments within hospitals and outpatient facilities.
Configurations
- STANDARD: ECG, ComfortCuff™ NIBP, DOX™ SpO2, HR, Temperature, Respiration and Nurse Call interface connection.
- OPTIONAL: ETCO2, INCO2, Arrhythmia and ST analysis, printer.
Features
- Monitors end-tidal CO2 and inspired CO2 accurately at high respiration rates.
- Gas monitoring with full occlusion clearing and high capacity water trap.
- Mini-Trends can display condensed tabular vital signs data to show recent monitoring activities.
- Compatible with popular Electronic Medical Records (EMR) systems for both large facilities and small offices.
- Easy-to-read 10.4" TFT color display.
- Easy to learn, easy to use - simplified menus and dedicated function keys.
Focus on your patients, not your monitor
The nGenuity™ patient monitor is the perfect choice for busy departments demanding accurate, reliable performance.
The nGenuity™ can monitor adult and pediatric patients in virtually every department. The innovative user interface features simplified menus and dedicated function keys for timely setups. The big, bright display with large numerics can be easily seen from across the room.
The nGenuity™ mounts quickly and easily to walls and rollstands.
ECG
Number of Leads: 3- or 5-Lead
Lead view: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead); I, II, or III (3-Lead)
Gain Selection: x0.5, x1, x2, and x4
Frequency Response: Diagnostic: 0.05 to 100 Hz (-3dB); Monitor: 0.5 to 40Hz (-3dB); ST: 0.05 to 40Hz (-3dB)
Electrosurgery Protection: Yes
Defibrillator Protection: Yes
Pacer Detection/Rejection: Yes
ST Accuracy: ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
ST Range: -6.0 to 60mm
Pulse Oximetry
Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified; complies with ISO 9919
Method: Dual wavelength LED
NIBP (Non-Invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 30 to 300 mmHg. Neonate: 20 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff Pressure: Adult/Pediatric: 300 mmHg; Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater
Clinical Accuracy: Complies with AAMI SP-10:2002
Heart (Pulse) Rate
Source: User selectable: Smart, ECG, Pleth, NIBP
Range: 20 to 300 bpm (30 to 240 bpm NIBP)
Accuracy: ±1 bpm or ±1% (ECG) whichever is greater; ±2 bpm or ±2% (NIBP) whichever is greater
Capnography (CO2)
Units: mmHg; kPa; Torr; %
Method: Non-dispersive infrared; autocalibrating
N20 Compression: Manual; On/Off, user selectable
Range: 0 to 99 mmHg; 0 to 12.5%
Flow, Sample Rate: Sidestream; 200 mL/min
Accuracy: ±2 mmHg, ±0.3 volume %, ±3kPa, or ±2 Torr at 200 mL/min & respiratory rate <= 120 bpm
Rise Time: 170 ms (10 to 90%) at 200 mL/min
Respiration
Rate: 6 to 150 bpm (ECG); 2 to 120 bpm (CO2)
Resolution: 1 breath/min
Accuracy: ±1% or ±1 breath/min, whichever is greater
Source: User selectable: Smart, CO2, ECG-TTI
Temperature
Channels: 1
Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
Display Resolution: ±0.1°C
Probe: YSI-400 and YSI-700 Series
Alarms
Indication: Audible; Visual
Silence: Yes; 2 minutes or permanent
Trends
Memory: 24 hr at 30 second intervals with a NIBP reading every 3 minutes
Display: tabular, graphical
Interface & Display
Keys: 9; membrane activated
Rotary Knob: Push and rotate; 24 steps/turn
Screen: 10.4 inch active color TFT
Resolution: Internal Display: 640 x 480 pixels; External Display: 640 x 480 pixels
Waveforms: 6, maximum
Waveform Types: ECG Leads I, II, III, aVR, aVL, aVF, V; Respiration; CO2; Pleth; ST Histograms
Sweep Speed: 6.25, 12.5, 25, or 50 mm/sec
Languages: English, Chinese, Czech, French, German, Italian, Plish, Portuguese, Russian, Spanish, Turkish
System Outputs
COM ports: RS 232 compatible; DB9 (Com1) Mini-DIN 8 (Com2)
Nurse Call: Contact switch; 3.5mm jack, 14 mm length
Defib/Sync: BNC connector
Video Port: High density D-sub 15-pin Serial VGA compatible
Printer (optional)
Type: Thermal line printer
Paper Speed: 12.5, 25 or 50 mm/sec
Physical Properties
Weight: 14 lbs; 6.4 kg
Size: 11 in (H) x 13 in (W) x 10.3 in (D); 28 cm (H) x 33 cm (W) x 26.2 cm (D)
Power Requirements
Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
Power Consumption: 35 Watts, typical
Battery: 1 sealed lead acid
Battery Life: 3 hours, typical
Recharge Time: 4.5 hours, typical
Environmental
Operating Temperature: 59° to 95°F (15° to 35°C)
Storage Temperature: 23° to 122°F (-5° to 50°C)
Operating Humidity: 15% to 90%, noncondensing
Classification
Medical Device: Class II Equipment (IIb EU)
Electrical Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection Against Ingress: IPX1
nGenuity™ Patient Monitor with CO2
$5,695.00>
nGenuity™ Patient Monitor without CO2
$3,695.00>
Mobile ACLS® Emergency Medical Kit
SM Series Basic Emergency Medical Kits
Special Offer for HM Emergency Medical Kit Owners
Heartsine samaritan® PAD 300P
Philips OnSite Defibrillator
Emergency Oxygen for the Dental Office
Onsite Team Training: BLS, CPR & AED
Online Bloodborne Pathogens Training
Online Emergency Medical Kit Training
DVD: Emergency Medicine in the Dental Office by S. Malamed
nGenuity™ Patient Monitor
VitalCare™ Patient Monitor
Tru-Align® X-Ray Positioning System
instadose Dosimeters
All Medications
Epinephrine Auto-Injectors
Albuterol
Nitroglycerin Tablets & Spray
Diphenhydramine
Flumazenil
Naloxone
Amalgam Separation & Disposal
Scrap Amalgam Waste Service
Sharps Recovery Disposal-by-Mail
Unused Medication Disposal-by-Mail
Sterilization Pouches
Environmental Barriers
Personal Protection
Surface Disinfectants
Spore Testing