VitalCare™ Patient Monitor
Multiple Configurations | Battery Management | Cost Effective
Proprietary ComfortCuff™ NIBP, pulse oximetry and predictive temperature in one compact, easily transported monitor. Ideal for spot-checks or continuous vital signs monitoring.
Features
- Proprietary ComfortCuff™ NIBP measures on inflation for faster, more comfortable readings.
- Choice of Criticare's DOX™ digital SpO2 or Nellcor OxiMax™ SpO2 technology.
- Audible and visual alarms are adjustable; providing instant notification in the manner you need them.
- Optional FILAC FasTemp™ or Alaris TurboTemp™ predictive temperature for quick, accurate measurements.
- Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.
Spot-check or continuously monitor three critical parameters - on neonates to adults - with a single monitor.
Designed to travel everywhere you do, the VitalCare™ patient monitor with integrated carry handle attaches quickly and easily to IV pole mounts or rollstands. Available in multiple configurations - with choice of Criticare or Nellcor oximetry - this VitalCare™ monitor provides maximum versatility and cost-effectiveness.
Smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily set-up for spot-checks or continuous monitoring, the VitalCare™ patient monitor adapts readily to hospital, clinical and transport requirements.
NIBP (Non-Invasive Blood Pressure)
Technique: Oscillometric during inflation
Measurement Cycle: < 40 sec. typical
Automatic Measurement Cycles (Selectable): 1 to 60 minute; 2 to 4 hour; STAT
STAT Mode: 5 minutes of continuous readings
Inflation Pressure Range Adult: 30 to 300 mmHg; Pediatric: 30 to 150 mmHg; Neonate: 20 to 150 mmHg;
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater over full range
Clinical Accuracy: SP-10:2002
Pulse Oximetry
Range: 1% to 99%
Resolution: 1%
Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified;
Accuracy (OxiMax only): 70% to 99% range: < 70%: unspecified;
Method: Dual wavelength LED
Audio: Tone with each detected pulse; pich varies with saturation
Heart (Pulse) Rate
Range: 20 to 300 bpm
Accuracy (DOX only): Greater of ±1 bpm or ±1% of reading; Unspecified for <30 or >240 bpm
Accuracy (OxiMax only): Greater of ±1 bpm or ±1% of reading; Unspecified for <30 or >240 bpm
Update Time: 1 second
Resolution: 1 bpm
Pulse Volume: 10 levels or Off
Temperature (FILAC)
Type: FasTemp
Method: Predictive or continuous
Channels: 1
Range: 86° to 109.4°F (30° to 43°C)
Accuracy Continuous Mode: ±0.2°F (±0.1°C)
Accuracy Predictive Mode: ±0.2°F (±0.1°C) for ranges 37° to 39°C (Compliant with EN 12470-3 and ASTM E1112:98)
Resolution: ±0.1°F or ±0.1°C
Predictive Response Time: Oral: 10 seconds typical; Axial: 10 seconds typical; Rectal: 10 seconds typical;
Temperature (Alaris)
Type: TurboTemp
Method: Predictive or continuous
Channels: 1
Predictive Mode Range: 96° to 106°F (35.6° to 41.1°C)
Continuous Mode Range: 80° to 106°F (26.7° to 41.1°C)
Accuracy: ±0.2°F (±0.1°C) (measured in calibrated water bath while in continuous mode)
Resolution: ±0.1°F or ±0.1°C
Predictive Response Time: 10 seconds typical (oral)
Alarms
Indication: Audible; Visual
Volume: 10 levels or OFF
Silence: Yes; 2 minutes or permanent
Trends
Memory: Last 24 hours
Parameters: NIBP, SpO2, pulse rate, temperature
Report Types: Single patient or Multi-patient; Selectable formats
Display
Type: LED
Parameters: SpO2, pulse rate, NIBP, temperature, pulse bar
Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size
Text: Alphanumeric LCD
Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish
System Outputs
COM Port: Serial, RS 232 compatible
Printer (optional)
Type: Thermal array
Tabular Mode: 1 to 60 minute intervals; 2 to 24 hour intervals; Auto on BP; Auto on Alarm; Off
Physical Properties
Weight: Base unit with battery: 6.95 lbs; 3.1 kg
Size: Base unit: 8.7 in (H) x 7.1 in (W) x 6.5 in (D); 22 cm (H) x 18 cm (W) x 16.5 cm (D)
Power Requirements
Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
Battery: 1 sealed lead acid
Battery Life: 8.0 hours, typical
Recharge Time: 6.5 hours, typical
Environmental
Operating Temperature: 32° to 113°F (0° to 45°C)
Storage Temperature: 23° to 122°F (-5° to 50°C)
Operating Humidity: 15% to 90%, noncondensing
Classification
Electrical Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection Against Ingress: IPX1, Drip-proof Equipment
VitalCare™ Patient Monitor
$1,995.00>
Mobile ACLS® Emergency Medical Kit
SM Series Basic Emergency Medical Kits
Special Offer for HM Emergency Medical Kit Owners
Heartsine samaritan® PAD 300P
Philips OnSite Defibrillator
Emergency Oxygen for the Dental Office
Onsite Team Training: BLS, CPR & AED
Online Bloodborne Pathogens Training
DVD: Emergency Medicine in the Dental Office by S. Malamed
nGenuity™ Patient Monitor
VitalCare™ Patient Monitor
Tru-Align® Laser-Aligning X-Ray Positioning System
All Medications
Epinephrine Auto-Injectors
Albuterol
Nitroglycerin Tablets & Spray
Diphenhydramine
Flumazenil
Naloxone
Amalgam Separation & Disposal
Scrap Amalgam Waste Service
Sharps Recovery Disposal-by-Mail
Unused Medication Disposal-by-Mail
OPTIM® 33TB Ready-to-Use Wipes
VacuBlu® Evacuation System Cleaner