VitalCare Patient Monitor

Multiple Configurations | Battery Management | Cost Effective

Proprietary ComfortCuff NIBP, pulse oximetry and predictive temperature in one compact, easily transported monitor. Ideal for spot-checks or continuous vital signs monitoring.

Features

  • Proprietary ComfortCuff NIBP measures on inflation for faster, more comfortable readings.
  • Choice of Criticare's DOX digital SpO2 or Nellcor OxiMax SpO2 technology.
  • Audible and visual alarms are adjustable; providing instant notification in the manner you need them.
  • Optional FILAC FasTemp or Alaris TurboTemp predictive temperature for quick, accurate measurements.
  • Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.

Spot-check or continuously monitor three critical parameters - on neonates to adults - with a single monitor.

Designed to travel everywhere you do, the VitalCare patient monitor with integrated carry handle attaches quickly and easily to IV pole mounts or rollstands. Available in multiple configurations - with choice of Criticare or Nellcor oximetry - this VitalCare monitor provides maximum versatility and cost-effectiveness.

Smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily set-up for spot-checks or continuous monitoring, the VitalCare patient monitor adapts readily to hospital, clinical and transport requirements.

NIBP (Non-Invasive Blood Pressure)

Technique: Oscillometric during inflation

Measurement Cycle: < 40 sec. typical

Automatic Measurement Cycles (Selectable): 1 to 60 minute; 2 to 4 hour; STAT

STAT Mode: 5 minutes of continuous readings

Inflation Pressure Range Adult: 30 to 300 mmHg; Pediatric: 30 to 150 mmHg; Neonate: 20 to 150 mmHg;

Resolution: 1 mmHg

Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater over full range

Clinical Accuracy: SP-10:2002

Pulse Oximetry

Range: 1% to 99%

Resolution: 1%

Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified;

Accuracy (OxiMax only): 70% to 99% range: < 70%: unspecified;

Method: Dual wavelength LED

Audio: Tone with each detected pulse; pich varies with saturation

Heart (Pulse) Rate

Range: 20 to 300 bpm

Accuracy (DOX only): Greater of ±1 bpm or ±1% of reading; Unspecified for <30 or >240 bpm

Accuracy (OxiMax only): Greater of ±1 bpm or ±1% of reading; Unspecified for <30 or >240 bpm

Update Time: 1 second

Resolution: 1 bpm

Pulse Volume: 10 levels or Off

Temperature (FILAC)

Type: FasTemp

Method: Predictive or continuous

Channels: 1

Range: 86° to 109.4°F (30° to 43°C)

Accuracy Continuous Mode: ±0.2°F (±0.1°C)

Accuracy Predictive Mode: ±0.2°F (±0.1°C) for ranges 37° to 39°C (Compliant with EN 12470-3 and ASTM E1112:98)

Resolution: ±0.1°F or ±0.1°C

Predictive Response Time: Oral: 10 seconds typical; Axial: 10 seconds typical; Rectal: 10 seconds typical;

Temperature (Alaris)

Type: TurboTemp

Method: Predictive or continuous

Channels: 1

Predictive Mode Range: 96° to 106°F (35.6° to 41.1°C)

Continuous Mode Range: 80° to 106°F (26.7° to 41.1°C)

Accuracy: ±0.2°F (±0.1°C) (measured in calibrated water bath while in continuous mode)

Resolution: ±0.1°F or ±0.1°C

Predictive Response Time: 10 seconds typical (oral)

Alarms

Indication: Audible; Visual

Volume: 10 levels or OFF

Silence: Yes; 2 minutes or permanent

Trends

Memory: Last 24 hours

Parameters: NIBP, SpO2, pulse rate, temperature

Report Types: Single patient or Multi-patient; Selectable formats

Display

Type: LED

Parameters: SpO2, pulse rate, NIBP, temperature, pulse bar

Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size

Text: Alphanumeric LCD

Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish

System Outputs

COM Port: Serial, RS 232 compatible

Printer (optional)

Type: Thermal array

Tabular Mode: 1 to 60 minute intervals; 2 to 24 hour intervals; Auto on BP; Auto on Alarm; Off

Physical Properties

Weight: Base unit with battery: 6.95 lbs; 3.1 kg

Size: Base unit: 8.7 in (H) x 7.1 in (W) x 6.5 in (D); 22 cm (H) x 18 cm (W) x 16.5 cm (D)

Power Requirements

Voltage: 100, 120, 220, 240 VAC; 50/60 Hz

Battery: 1 sealed lead acid

Battery Life: 8.0 hours, typical

Recharge Time: 6.5 hours, typical

Environmental

Operating Temperature: 32° to 113°F (0° to 45°C)

Storage Temperature: 23° to 122°F (-5° to 50°C)

Operating Humidity: 15% to 90%, noncondensing

Classification

Electrical Protection: Class I Equipment

Degree of Protection: Type CF, Defibrillator-proof

Protection Against Ingress: IPX1, Drip-proof Equipment

VitalCare Patient Monitor

    • Qty:

$1,995.00

Recommended Equipment

Criticare Rollstand for VitalCare Patient Monitor

$350.00

    • Qty: